µXTR Tips: Big Performance for Small Sample Volumes

Our PROTip: Eliminate manual, time-consuming steps without sacrificing performance.

As sample volumes shrink and sensitivity demands increase, researchers need extraction tools that can deliver cleaner samples, higher concentration factors, and faster workflows. µXTR tips deliver our innovative and patented dispersive pipette extraction technology with a low-retention frit.

Achieve High Concentration with Minimal Elution Volumes

µXTR tips are ideal for low-volume applications. The low-retention frit design minimizes dead volume and elution volume. Loose sorbent chemistry within the pipette tip increases interaction efficiency between sample and sorbent to maximize recovery. This design allows for elution volumes as low as 25 µL and eliminates solvent evaporation and sample reconstitution steps. Without these additional steps, analytical laboratories can save time and reduce analyte loss.

Benefits of µXTR tips and low-volume elution: 

  • up to 8x analyte concentration factors
  • improved detection sensitivity
  • reduce sample handling
  • lower solvent consumption
  • faster overall workflows
  • improved analyte recovery

What is dispersive pipette extraction technology?

Unlike traditional SPE, XTR tips utilize a patented Dispersive Pipette XTRaction technology. Sorbent chemistry is loosely contained within pipette tips; during aspirate and dispense cycles, the disperser actively mixes sample and sorbent, increasing interaction efficiency.

This product is ideal for clinical and/ or forensic toxicology laboratories that need to increase throughput, improve detection sensitivity, reduce analyte loss and streamline LC-MS/MS testing. DPX offers automation support and custom method development.

Product Specifications: µXTR tips

Tip size and format: 

  • Hamilton 300 µL
  • Integra 300 µL
  • Tecan MCA and FCA 200 µL

All standard DPX chemistries are available: µXTR tips can hold 1-3 mg of sorbent

See XTR chemistry options

XTR μElution -300 μL size tip

Applications

Discover a faster, simpler approach to steroid hormone analysis. μXTR tips with Supel™ Swift HLB sorbent from DPX Technologies enable rapid, automated extraction of nine steroid hormones from serum, delivering excellent sensitivity, reproducibility, and recovery. The DPX method can process up to 96 samples and eliminates solvent evaporation, helping clinical laboratories streamline LC-MS/MS testing while maintaining consistent results.